                        | Differential Pressure Switches |  |  |  
                    |  |  
                    | 
                      
                        | 1) Diaphragm type Fixed    DP Differential Pressure Switches  • Various Ranges from 0 to 2 mm Wc    up to 0 to 7 bar •  Accuracy: +/- 1% FS
 •
  Temperature Range: -10 to 80 Degree C (for high temperature use of impulse    tube is advisable) •  Migration: Impossible
 •  No. of Switches: one no.
 •  Type of Switches: Micro Switches -    SPDT
 •  1 A 230 V AC or, 2 A 250 V AC, 5 A    250 V AC
 •  Housing IP 54, IP 65 & Flameproof
 •  Pressure Housing Plastic, MS or,    SS 316
 •  Sensing Diaphragm : Nitrile,    Teflon or Neoprene
 •  Process Connection hose fitting or, ¼” BSP (F)
 |  
                        |  |  
                        |  |  
                        |  |  
                        |  |  
                        | 2) Diaphragm type    Adjustable DP Differential Pressure Switches   •  Various Ranges from 0 to 150 mm Wc    up to 0 to 2500 mm Wc •  Differential : Adjustable
 • Accuracy: +/- 1% FS
 • Temperature Range : -10 to 80 Degree C (for high temperature use    of impulse    tube is advisable)
 • Migration : Impossible
 • No. of Switches: one no.
 • Type of Switches: Micro Switches -    SPDT, 5 A 250 V AC
 • Housing IP 54, IP 65
 • Pressure Housing MS
 •  Sensing Diaphragm: Neoprene
 •  Process Connection hose fitting or, ¼” BSP (F)
 |  
                        |  |  
                        |  |  
                        |  |  
                        |  |  
                        |  3) Flameproof      Differential Pressure Switches
 • Flameproof Differential Pressure      Switches certified by BASEEFA,    NABL & CCOE •  Various Ranges: from 0 to 150 mm      Wc upto 0 to 400 Bar
 •  Differential (Dead Band): Fixed      (Within 10% of set value) Or,   Adjustable
 • Sensing Element: Diaphragm      (PTFE, Neoprene or, SS 316) or Piston
 •  Enclosure : Flameproof to group      IIC
 |  
                        |  |  
                        |  |  
                        |  |  
                        |  |  
                        | 4) 2 SPDT Differential    Pressure Switches  •  Various Ranges from 0    to 3.6 bar •Accuracy : +/- 1% FS
 •Temperature Range : -10 to 80 Degree C (for high temperature use    of impulse    tube is advisable)
 • Migration : Impossible
 • No. of Switches : Two    nos.
 • Type of Switches :    Micro Switches - 2 nos.SPDT  5 A 250 V AC
 • Housing IP 54 or,IP 65
 • Pressure Housing :    Aluminium, Brass or, SS 316
 • Sensing Diaphragm :    Teflon or Neoprene
 • Process Connection hose fitting or, ¼” BSP (F)
 |  |  
                    |  |  
                    |  |  |  |