Home   Company Profile   Our Products   Product Brand   Contact Us   Enquiry  
Slide 1
Slide 2
Slide 3
 
 
Our Products
 
Drucker Diagnostics / QBC
 

Fluorescence Microscopy Products

 

The ParaLens Advance is a fluorescence microscopy attachment that turns any light microscope into a powerful diagnostic tool for use in a range of clinical and research applications. With its patent-pending design, the ParaLens Advance is easier to use and less expensive than a conventional fluorescent microscope, making it an excellent choice for users trying to make the most of their equipment budget, or anyone else desiring simplicity and convenience.

Applications

 

A portable, easy-to-use alternative to more expensive fluorescent microscopes, the ParaLens Advance can be found in the front lines of the fight against malaria and other tropical diseases. It is equally at home in clinical and research settings, and it features a range of customization options to meet the needs of any user. Portable and effective even in rugged environments, the complete system weighs less than eight (8) pounds and conveniently fits into a small, durable hard shell carrying case. The ParaLens Advance, when used with fluorescence staining, provides an ideal and cost effective tool for research, fieldwork, and diagnosis of tropical diseases, including : 

 

1. Malaria – LED fluorescence staining is a fast and easy way to test for malaria caused by plasmodium parasites. The Malaria Test Kit with pre-stained sample tubes is ideally suited to malaria diagnosis.

 

2. Acid-Fast Bacteria (AFB) – Test for acid-fast bacteria such as Tuberculosis using a QBC F.A.S.T. AFB Kit. Recommended by the World Health Organization (WHO), fluorescence microscopy is quickly becoming the method of choice for detecting acid-fast bacteria. The F.A.S.T. AFB Kit follows the recommended WHO guidelines and quickly provides accurate identifications of AFB like TB from a sputum sample in just three minutes.


3. Other Diseases – The ParaLens Advance can also be used to screen for a range of other diseases, including filariasis, blastocystis, babesiosis, and Lyme Disease. For more information, contact the Drucker Diagnostics sales team directly.

 

How it Works

The ParaLens Advance attaches to any compound light microscope as an objective. A number of adapters are available for those few microscopes that do not use RMS threading. A detachable filter fits in the body of the ParaLens Advance and is securely held in place with powerful magnets. An LED light source connects to the filter arm with a simple turn of a screw. To conduct fluorescence microscopy screening, a sample is first treated with a fluorescent dye. When the LED light is directed onto the stained sample, the sample becomes excited and emits light of a new wavelength.

 
 
QBC Capillary Centrifuge
 
  • Hematology or Immunology
  • 20 Tube Capacity
  • For use with QBC AccuTube
  • Preset Runtime
  • Preset Speed
  • Lightweight and Ultra-Compact
  • Rugged and Reliable in the Field
  • 2 Year Warranty
 

Electrical Specifications


 
  • Electrical
  •  
    • 48 VDC ± 3 VDC, 2.7
      ADC Maximum, steady state

  • Power Input Cable
  •  
    • 4.8 in (12.2 cm)
      (power pack)

  • Input: 100 – 240 VAC, 47 – 63 Hz
  • Output: 48 VDC, 2.7 amp
  • DC Output Cable: 4 ft. (1.2 m)

  • AC Line Cord
     
    • (Standard Cord): 7.5 ft. (2.3 m) 
      (Continental European Cord): 8.2 ft. (2.5 m)

General Specifications

Dimensions (with lid closed) – W 9.25” x D 11.75” x H 5” 
Capacity – Up to 20 QBC AccuTubes
Weight (with rotor and cover installed) – 6.2 lbs. (2.8 kg)
Nominal Speed – 12,000 rpm ± 80 rpm
Relative Centrifugal Force (RCF) At nominal speed – 14,387 g
Rotor Capacity – 20 numbered tube slots
Electronic Timer – 300 seconds spin; 15-20 seconds deceleration
Electro-Mechanical Safety Interlock – Lid must be closed and latched before motor can be energized. Lid remains locked until rotor stops.

 

Included Parts:

Capillary Centrifuge Rotor
Power Pack

 
 
Test Kits
 

Quality management often requires a fast decision whether goods fulfill their defined quality criteria. To quickly analyze and draw these conclusions, rapid test kits are an essential and efficient tool.

 

At different points of care, which range from grain reception points to quality control laboratories, operators with various qualification levels require easy-to-use test kits with qualitative and/or quantitative results. To cater for these different needs, Romer Labs has developed a number of test kit solutions consisting of lateral flow devices (LFDs), enzyme linked immunosorbent assays (ELISAs), and fluorometric assays. A complete overview can be found below. 

 
 
 
 

Reference Materials

 

 

High quality reference materials are a must for accurate and reliable results in any analysis. Under the brand Biopure™, Romer Labs offers the broadest range of reference materials currently available on the market. These high quality products are available in crystalline or liquid form for mycotoxins, residues and contaminants.

 

The product range is completed by internal standards, a range of stable, fully isotope labeled 13C standards in a ready-to-go liquid form. Furthermore, Romer Labs offers quality control materials for specific mycotoxins in different matrices.

 

State-of-the-art analytical methods (HPLC, LC-MS, NMR, etc.) provide the quality assurance necessary for identification, characterization and quality control. Each calibrant is accompanied by a certificate of analysis that follows ISO and Eurachem guidelines.
 
 
 
The NGAL Test
 

Until now, assessing risk of AKI in critically ill patients has relied on changes in serum creatinine and urine output, physiologic endpoints that are delayed, non-specific, and impacted by extrarenal factors such as nutritional status and muscle mass.

The NGAL Test is designed to help clinicians identify levels of urinary or plasma NGAL, a biomarker that rises rapidly in response to kidney injury, preceding changes in creatinine by as much as 2 to 3 days.

 

By identifying patients at risk of AKI early, clinicians can take more appropriate action to manage fluid levels, avoid nephrotoxic agents, and potentially prevent permanent, kidney damage.

 

 

 

EPA Registered Products

 
These products provide a cleaning product ready to use in a few hours once it is released into a container of water.
 

Selectrocide® 12G

 

The Selectrocide® 12G generates 6 gallons of 500 ppm ultra-pure ClO₂ and is intended for applications that require large amounts of pure ClO₂. The 12G is easy to use. Simply remove the sachet and place it in a covered tank or bucket and generate for 2 hours. Dilute the solution to fit your needs. The 12G is registered with the Environmental Protection Agency as a pesticide and falls within the lowest toxicity categories. The 12G is also recognized and registered with the Organic Materials Review institute. The 12G is commonly used for agricultural applications, hard, non-porous surfaces, food contact surfaces and general disinfection.

 

 

Features and Benefits :

 

 
  • Provides 30 gallons of hospital grade disinfectant
  • Provides 600 gallons of food contact surface sanitizer
  • Requires very little storage space
  • Ships dry to save on costs
  • No activators, or mixing of chemicals required
  • Effective deodorizer

 

Industry Usage :

 

 
  • Food processing facilities
  • Greenhouse/Grow operations
  • High purity water systems
 
 

QBC® STAR™

Dry Hematology
 
 
  • Fully Automatic
  • Simple, Single Button Operation
  • No Liquid Reagents
  • 9 Parameter, 2 Part Differential CBC
  • For Capillary and Venous Blood
  • Accurate Reads without the Calibration
  • Built-in Printer
  • 1 Year Warranty
 
Collect Sample
Place Tube in the Analyzer
Press Start
 

QBC STAR Operating Ranges

 
Parameters
Operating Range
Precision
Hematocrit (Hct) (%) 15 - 65 2% C.V.
Hemoglobin (Hgb) (g/dL) 5.0 - 20.0 1.9% C.V.
Mean Corpuscular Hemoglobin
Concentration (MCHC) (g/dL)
25 - 37.3 N/A
WBC Count (x 10⁹/L) 1.6 - 99.9 6.4% C.V.
Granulocyte (x 10⁹/L) 0.8 - 70 < 3.2 S.D.
Granulocyte % (Gran %) 1 - 99 N/A
Lymphocyte/Monocyte Count (x 10⁹/L) 0.8 - 99.9 < 3.2 S.D.
Lymphocyte and Monocyte %
(Lymph/Mono %)
1 - 99 N/A
Platelet Count (x 10⁹/L) 20 - 999 6.0% C.V.
 

General Specifications :

 
Dimensions (in.) – W 16 x D 16.3 x H 16.3 
Dimensions (cm.) – W 40.6 x D 41.4 x H 41.4 
Weight – 19 lbs. (8.6 kg)
Noise – <70 db @ 3 ft
Sample Volume – 70 µL
Display – LCD, Resolution 160x160
Printout – 58 mm thermal recorder paper
 

Electrical Specifications :

 
Voltage Input – 100 – 240 VAC
Frequency – 50 – 60 Hz
Current Output – 5.21 A (Peak)
 
Connectivity :
 
USB – 3 external Ports
Ethernet (Wired) – RJ45
LIS Integration – Possible
 

Operating Environment :

 
Temperature – 16°C – 32°C
Humidity – 10% – 95% Non-condensing
 
 
 
Lab Blenders
 
   
MiniMix 100 range          

Lab blenders for samples up to 10 g             

 
BagMixer 400 range

Lab blenders for samples up to 40 g

 
JumboMix 3500 range

Lab blenders for samples up to 400 g

 
BEST SAMPLE PREPARATION
 
BagMixer lab blenders guarantee the best preparation before microbiological analysis for all samples from 10 g to 400 g and enable optimal bacterial extraction in 30 to 60 seconds. World best-sellers with more than 18.000 units working in labs, BagMixer is the icon of INTERSCIENCE, the only company to be manufacturer of blenders & sterile bags for perfect work comfort. All BagMixer enjoy a 3 year guarantee worldwide.
 
 
 
 
IMPORTANT LINK PRODUCT BRANDS ADDRESS
     
HOME DRUCKER DIAGNOSTICS USA 92, Charuchandra Place ( East )
COMPANY PROFILE ROMER LABS GmbH Kolkata : 700 033, West Bengal, India.
OUR PRODUCTS BIOPORTO DIAGNOSTICS DENMARK 91 33 4061 6274
CONTACT US SELECTIVE MICRO TECHNOLOGIES USA  clonezyme.biotek@gmail.com
ENQUIRY INTERSCIENCE FRANCE   
  MICROGEN BIOPRODUCT UK  
     
Site Powered By : www.calcuttayellowpages.com