Products ... |
|
For Compositions, kindly gothrough - |
|
|
The Products that we deal in - |
|
- SPECTROCHEMICAL STANDARDS FOR ANALYSIS OF ALUMINIUM AND ITS ALLOYS, AND SETTING UP SAMPLES
- SPARES & CONSUMABLES FOR “ LECO”, CARBON & SULPHUR DETERMINATOR, CARBON, SULPHUR, OXYGEN, NITROGEN AND HYDROGEN IN STEEL CALIBRATION STANDARDS, COAL AND COKE STANDARDS, GRAPHITE CRUCIBLES & ELECTRODES FOR SPECTROMETER.
- BRITISH CHEMICAL & SPECTROSCOPIC STANDARDS (BOTH FERROUS AND NON- FERROUS METALS)
- BIOLOGICAL AND ENVIRONMENTAL STANDARDS, ZINC AND ZINC ALLOY CERTIFIED REFERENCE MATERIALS ON ORES, FUELS, COAL & COKE ETC.
- SPECTORGRAPHIC STANDARDS REFERENCE MATERIALS FOR COPPER, LEAD & NICKEL BASE ALLOYS.
- SPECTROSCOPIC STANDARDS OF CHILL CAST IRON, LOW ALLOY STEEL, CALCIUM TREATED STEEL, STAINLESS & HIGH TEMPARATURE STEEL, NICKEL BASE ALLOYS, COPPER BASE ALLOYS, COBALT BASE ALLOYS AND SPECIAL STEEL ALLOYS FOR XRF SPECTROMETER.
- CERTIFIED REFERENCE MATERIALS ON BASE METAL ORES, NOBLE METAL BLASTFURNACE SLAG, URANIUM ORE, COMMERCIALLY PURE COPPER, SOIL, ROCK, STEAM SEDIMENT.
- SPECTROGRAPHIC STANDARDS FOR CAST IRON.
- CERTIFIED REFERENCE MATERIALS AND SPECTROSCOPIC STANDARDS.
- CONOSTAN METTALLO ORGANIC STANDARDS AND BASE OIL STANDARDS.
- CERTIFIED ECRM SPECIAL ALLOY, CAST IRON LOW ALLOY, IRON, Cu, Ni, Cr. Mo, Iron Reference Materials, AUSTENITIC ( NICKEL RESIST) IRON REF. MATERIALS, CR. IRON, REFERENCE MATERIALS, BRONZE COBALT, CUPRO-BRELLIUM, NICKEL ALUMINIUM REFERENCE MATERIALS.
- CERTIFIED REFERENCE MATERIALS (CHEMICAL STANDARDS) BOTH OF FERROUS AND NON- FERROUS METALS, REFACTORIES, ROCKS, MINERALS & ORES GLASS SANDS ETC.
- CERTIFIED REFERENCE MATERIALS FOR ECRM STANDARDS OF FERROUS, SLAG, ORE & REFRACTORIES. CERTIFIED REFERENCE MATERIALS OF IRON, STEEL, FERRO ALLOYS, SLAG & FLOURSPAR.
- CERTIFIED REFERENCE MATERIALS ON PURE IRON, CARBON STEEL, PIG IRON , LOW ALLOY STEEL HIGH TENSILE STRUCTURAL STEELS, CASE HARDENNING STEEL, HEAT RESISTING STEEL, TOOL STEEL, HIGH SPEED STEEL, FERRO ALLOYS, IRON ORE, FLOURSPAR, BLAST FURNACE SLAG.
- CERTIFIED REFERENCE MATERIALS ON BIO MEDICAL ENVIRONMENTAL AND STANDARDS ON POLLUTION CONTROL PRODUCTS, PESTICIDE CONTROL STANDARDS ETC.
- GRAPHITE CRUCIBLES, DISCS, FOR SPECTROMETER CERTIFIED REFERENCE MATERIALS ON IRON, NICKEL, COPPER, COPPER, ZINC, ALUMINIUM, MAGNESIUM, TIN. LEAD, SOLDER, TITANIUM, COBALT, ZIRCONIUM, NOBEL AND PRECIOUS METALS, BINARY ALLOYS, SETTING UP SAMPLES, CHECK CONTROL SAMPLES AND IN CHIPPING OF ABOVE AND GASES IN METALS, ROCKS, ORES, SLAG, FERRO ALLOYS, COAL & COKE & OIL ETC.
- SRM CERTIFIED REFERENCE MATERIALS AND SPECTROGRAPHIC STANDARDS, AS ABOVE.
- NML STANDARDS (CHEMICAL STANDARDS) ON FERRO ALLOYS, FERROUS AND NON- FERROUS METALS (REFRACTORY STANDARDS)
- MARINE & ENVIRONMENTAL STANDARDS.
- CERTIFIED REFERENCE MATERIALS ON OXYGEN, NITROGEN, HYDROGEN, CARBON AND SULPHUR IN STEEL PURE IRON, BINARY ALLOYS.
- CERTIFIED REFERENCE MATERIALS LIKE ROCK STANDARDS, SEDIMENTARY ROCKS, METAMORPHIC ROCKS AND MINERALS, ORE AND SEMI PROCESSED ORE REFERENCE MATERIALS. COAL REFERENCE MATERIALS, AND HEAVY MINERALS PROCESSED MATERIALS.
- FOR PIG AND CAST IRON, UNALLOY, LOW ALLOY STEEL, FERRITIC STAINLESS STEELS, AUSTENITIC STAINLESS STEEL, DYNAMO & TRANSFORMER STEEL, CERTIFIED REFERENCE MATERIALS.
- AQUEOUS SOLUTIONS: ICP, AAS.
|
|
We are also in a position to supply you various Metallurgical, petroleum, Paint Testing Equipment, High Purity Metals, and other Test & Measuring Instruments |
|
CANON® GLASS CAPILLARY VISCOMETERS SIZE RANGES & EXPANDED UNCERTAINTY |
|
Specifications For CANNON® Viscometers |
|
Table 1
Cannon-Fenske, Cannon-Ubbelohde, and
Cannon-Manning Viscometers |
Table 2
Ubbelohde Viscometers |
|
|
Size |
constant. cSt/s |
Range centistokes* |
25 |
0.002 |
0.5 to 2 |
50 |
0.004 |
0.8 to 4 |
75 |
0.008 |
1.6 to 8 |
100 |
0.015 |
3 to 15 |
150 |
0.035 |
7 to 35 |
200 |
0.1 |
20 to 100 |
300 |
0.25 |
50 to 250 |
350 |
0.5 |
100 to 500 |
400 |
1.2 |
240 to 1200 |
450 |
2.5 |
500 to 2500 |
500 |
8 |
1600 to 8000 |
600 |
20 |
4000 to 20 000 |
650 |
45 |
9000 to 45 000 |
700 |
100 |
20 000 to 100 000 |
|
Size |
constant. cSt/s |
Range centistokes* |
0 |
0.001 |
0.3 to 1 |
0C |
0.003 |
0.6 to 3 |
OB |
0.005 |
1 to 5 |
1 |
0.01 |
2 to 10 |
1C |
0.03 |
6 to 30 |
1B |
0.05 |
10 to 50 |
2 |
0.1 |
20 to 100 |
2C |
0.3 |
60 to 300 |
2B |
0.5 |
100 to 500 |
3 |
1.0 |
200 to 1000 |
3C |
3.0 |
600 to 3000 |
3B |
5.0 |
1000 to 5000 |
4 |
10 |
2000 to 10000 |
4C |
30 |
6000 to 30000 |
4B |
50 |
10000 to 50000 |
|
|
Glass Capillary Viscometers
Why does CANNON offer so many different types of glass capillary viscometers? Primarily because no single capillary viscometer is ideally suited for all kinematic viscosity determinations. Individual analysts also have their own preferences. The brief descriptions on the following page may assist you in determining which viscometer is most appropriate for your particular application. Feel free to contact CANNON with your questions. Our experienced staff would be happy to assist you.
Expanded Uncertainty
Instead of listing the precision of our glass capillary Viscometers, we now provide the expanded uncertainty. This is the universally accepted statistic when dealing with calibration data. In order to obtain A2LA accreditation (see page 1), we were required to determine and specify the expanded uncertainty for all our calibration data.
ISO publications define expanded uncertainty as "quantity defining the interval about the result of a measurement within which the values that could reasonably be attributed to the measurement may be expected to lie with a high level of confidence."
Our use of expanded uncertainty instead of precision does not reflect any change in the accuracy or quality of our viscometer. It is a statistical term that is more comprehensive than precision. When comparing the accuracy of viscometers it is essential that the expanded uncertainty be specified. |
|
|
VISCOSITY STANDARDS
Viscosities for all standards sold by CANNON are based on the National Institute of Standards and Technology (NIST) value of 1.0016 mPa.s (centipoise) for water at 20°C (68°F). All standards are traceable to the NIST. CANNON has been granted ISO 9002 registration for the manufacture and certification of viscosity standards. Nominal or approximate values are listed in the following tables. Values for viscosity, kinematic viscosity, and density at :he temperatures listed below are printed on the label. Viscosity values at other temperatures in the range of 20°C to 100°C (68°f to 212°F) can be supplied for these standards at an additional charge. Unless otherwise noted, viscosity standards are sold in 470 ml (1 pint) bottles. Bulk quantities are available on special order. We invite your inquiries. |
|
Table I |
|
|
Approximate Kinematic Viscosity in mm2/s (Centistokes) |
Saybolt Viscosity |
Catalog Number |
Viscosity Standard |
20°C
68°F |
25°C
77°F |
37.78°C
100°F |
40°C
104°F |
50°C
122°F |
60°C
140°F |
98.89°C
210°F |
100°C
212 °F |
SUS
100°F |
SUS
210°F |
SFS
122°F |
9727-C10 |
N.4(b) |
0.47 |
0.45 |
0.41 |
0.4 |
- |
- |
- |
- |
- |
- |
- |
9727-C15 |
N.8(b) |
0.77 |
0.72 |
0.63 |
0.62 |
- |
- |
|
- |
- |
- |
- |
9727-C20 |
Nl.0(b) |
1. 3 |
1.2 |
1 |
0.97 |
0.91 |
_ |
- |
- |
- |
- |
- |
9727-C25 |
S3(a) |
4.6 |
4 |
3 |
2.9 |
0.4 |
- |
1.2 |
1.2 |
- |
- |
- |
9727-C30 |
S6 |
11 |
8.9 |
6 |
5.7 |
4.4 |
- |
l.8 |
1.8 |
- |
- |
- |
9727-C32 |
N10 |
21 |
17 |
11 |
10 |
7.3 |
- |
2.7 |
2.7 |
- |
- |
- |
9727-C35 |
S20 |
44 |
34 |
20 |
18 |
13 |
- |
3.9 |
3.8 |
100 |
- |
- |
9727-C37 |
N35 |
87 |
66 |
35 |
32 |
21 |
- |
5.4 |
5.3 |
170 |
- |
- |
9727-C40 |
S60 |
170 |
120 |
60 |
54 |
35 |
- |
7.3 |
7.3 |
280 |
- |
- |
9727-C42 |
NI00 |
330 |
230 |
110 |
97 |
60 |
- |
11 |
11 |
500 |
- |
- |
9727-C45 |
S200 |
660 |
460 |
200 |
180 |
105 |
- |
17 |
16 |
930 |
86 |
- |
9727-C47 |
N350 |
1 300 |
850 |
350 |
310 |
170 |
- |
24 |
23 |
- |
110 |
- |
9727-C50 |
S600 |
2400 |
1600 |
600 |
520 |
2SO |
- |
34 |
33 |
- |
150 |
130 |
9727-C52 |
NI000 |
3400 |
2400 |
- |
940 |
550 |
350 |
- |
SO |
- |
- |
- |
9727-C55 |
S2000 |
9600 |
5900 |
2000 |
1700 |
890 |
- |
72 |
69 |
- |
361 |
- |
9727-C57 |
N4000 |
20 000 |
12000 |
- |
3400 |
1600 |
850 |
- |
120 |
- |
- |
- |
9727-C60 |
S8000 |
41 000 |
25000 |
8000 |
6700 |
3200 |
- |
- |
240 |
- |
- |
- |
9727-C62 |
N15000 |
77 000 |
47000 |
- |
13 000 |
6100 |
3000 |
- |
360 |
- |
- |
- |
9727-C65 |
S30000 |
- |
89000 |
28000 |
23000 |
1 1 000 |
- |
- |
630 |
- |
- |
- |
|
|
Table II |
|
|
Approximate Viscosity in mPa.s (Centipoise) |
Catalog Number |
Viscosity Standard |
20°C
68°F |
25°C
77°F |
37.78°C
100°F |
40°C
104°F |
50°C
122°F |
60°C
140°F |
98.89°C
210°F |
100°C
212 °F |
9727-C10 |
N.4(b) |
0.31 |
0.29 |
0.26 |
0.26 |
- |
- |
- |
- |
9727-C15 |
N.8(b) |
0.66 |
0.62 |
0.54 |
0.52 |
- |
- |
- |
- |
9727-C20 |
N1.0(b) |
1 |
0.93 |
0.78 |
0.76 |
0.71 |
- |
- |
- |
9727-C25 |
S3 |
3.9 |
3.3 |
2.5 |
2.4 |
1.9 |
- |
0.9 |
0.9 |
9727-C30 |
S6 |
9.1 |
7.6 |
5.1 |
4.8 |
3.7 |
- |
1.5 |
1.4 |
9727-C32 |
N10 |
18 |
15 |
9.4 |
8.8 |
6.2 |
- |
2.2 |
2.2 |
9727-C35 |
S20 |
39 |
31 |
18 |
16 |
11 |
- |
3.3 |
3.2 |
9727-C37 |
N35 |
76 |
57 |
30 |
27 |
18 |
- |
4.4 |
4.3 |
9727-C40 |
S60 |
140 |
100 |
51 |
46 |
30 |
- |
6.1 |
6.0 |
9727-C42 |
N100 |
290 |
210 |
94 |
84 |
50 |
- |
9.2 |
9 |
9727-C45 |
S200 |
580 |
400 |
170 |
150 |
90 |
- |
14 |
13 |
9727-C47 |
N350 |
1100 |
750 |
310 |
270 |
150 |
- |
20 |
19 |
9727-C50 |
S600 |
2100 |
1400 |
530 |
450 |
240 |
- |
29 |
28 |
9727-C52 |
N1000 |
2900 |
2000 |
- |
500 |
460 |
280 |
- |
65 |
9727-C55 |
S2000 |
7600 |
4900 |
1700 |
1500 |
770 |
- |
65 |
62 |
9727-C57 |
N4000 |
17000 |
11 000 |
- |
2900 |
1400 |
730 |
- |
100 |
9727-C60 |
S8000 |
33 000 |
20 000 |
7000 |
5900 |
2800 |
- |
- |
200 |
9727-C62 |
N15000 |
68 000 |
41000 |
- |
11000 |
5400 |
2600 |
_ |
300 |
9727-C65 |
S30000 |
- |
80000 |
25000 |
21000 |
9500 |
- |
- |
540 |
|
top |
|
|