|   SPECIFICATIONS 
                                     
                                    | 
                              
                               
                                |   Construction:  | 
                                  Tubular 
                                    , rigid, electro statically powder coated 
                                    MS steel sections. / Aluminium / S. S/ As 
                                    required in Qty.  | 
                              
                               
                                |   Table 
                                    main tray :  | 
                                  
                                     
                                      Stainless steel ( 597 mm ´ 360 mm 
                                      )  
                                    | 
                              
                               
                                |   Mobility:  | 
                                  
                                     
                                      Large anti-static caster wheels for absolutely 
                                      smooth movement. Front castors with individual 
                                      brakes . 
                                    | 
                              
                               
                                |   Cylinder 
                                    yokes :  | 
                                  
                                     
                                      Gas specific ( Pin – indexed ) yoke 
                                      with sliding stainless steel claming bars 
                                      & Screw P/A for easy handing . 
                                       
                                      Two 
                                        each for oxygen & nitrous oxide ( 
                                        five liters water capacity ) ( cylinders 
                                        to be ordered separately ). 
                                     
                                    | 
                              
                               
                                |   Pressure 
                                    Gauges :   | 
                                   
                                    Large 
                                    diameters ( 63 mm ) two each for oxygen & 
                                    nitrous oxide, fitted at convenient angle 
                                    for high visibility & clarity. 
                                      | 
                              
                               
                                |   Regulators 
                                    :   | 
                                  
                                    Designed 
                                      for higher efficiency & reliability, 
                                      two each for oxygen & nitrous oxide. 
                                       
                                      Nitrous oxide regulators are activated only 
                                      when oxygen regulators are pressurized to 
                                      minimize the risk of administering 100% 
                                      nitrous oxide. 
                                    | 
                              
                               
                                |   Rotameters 
                                    :   | 
                                  
                                    Long 
                                      ( 230 mm ) rotating bobbin flowmeters calibrated 
                                      in double / triple scale for accuracy & 
                                      clarity in reading . 
                                      Oxygen : 100 ml / min to 10 liters / min 
                                      . 
                                      Nitrous oxide : 200 ml / min to 12 liters 
                                      / min. 
                                    | 
                              
                               
                                |   Oxygen 
                                    failure warning device :   | 
                                  
                                     
                                    Pneumatic 
                                      device which activates audible ( oxygen 
                                      failure alarm for a minimum of 7 seconds) 
                                      when oxygen supply pressure falls to 205 
                                      Kpa ( 30 psi ) its starts ringing. With 
                                      visual & mute switch.  
                                    | 
                              
                               
                                |   Vaporizers 
                                    :  | 
                                   
                                     
                                    One 
                                    Plenum type vaporizer for ether supplied as 
                                    stadard. Space for two more vaporizers (Available 
                                    at extra cost) 
                                    Not Return Cum Pressure relief valve: Minimises 
                                    risk of backflow of gases. Blows off when 
                                    pressure exceeds 200 cm / H20 relief valve 
                                    column.  | 
                              
                               
                                |   Breathing 
                                    Attachment :   | 
                                  Standard 
                                    magill,s circuit with change over unit ( open 
                                    circuit to close circuit & vice versa). 
                                    Emergency Oxygen outlet at table label (+O2 
                                    ).  | 
                              
                               
                                |   Top 
                                    tray :   | 
                                  
                                    Rigid 
                                      top tray for monitors , load capacity up 
                                      to 22 Kg. 
                                    | 
                              
                               
                                |   Extra 
                                    pipeline connection :  | 
                                  Two 
                                    built –in self sealing Schrader type 
                                    oxygen outlet ( 4.22 kg / cm2 ) for driving 
                                    Ventilators & other devices. Extra one 
                                    for N2O & air pipeline connection.  | 
                              
                               
                                | Circle 
                                  Absorber :  | 
                                Circle 
                                  Absorber can be securely mounted on the left 
                                  & right of the main frame. | 
                              
                               
                                | Dimensions 
                                  :  | 
                                Height 
                                    : 156 cm depth : 55 cm width : 61 cm length.  | 
                              
                               
                                | Weight 
                                  : | 
                                   
                                    Unpacked 70v kg.  | 
                              
                               
                                | Accessories 
                                  :  | 
                                 
                                    Given inside drawer.   | 
                              
                               
                                |   | 
                                  | 
                              
                               
                                | In 
                                  built Hypocic Gaurd System ensures minimum 25% 
                                  Oxygen in the mix gas and shuts flow of nitrous 
                                  oxide wwhen oxygen is closed.  |