MEDIWASTE INCINERATOR  

Emission Treatment Facilities

 

Secondary Chamber: The Secondary Chamber is mainly incorporated with the system for re-burning of emission. The chamber gas residence time shall be at least one second at 10500C ±500C.

 

Dilution: A fresh air incorporated with the system for dilute of flue gases through a powerful blower.

 

Gravity Settling Chamber: The gravity settling chamber is dust and solid collection equipment. Consisting of a chamber in which the gas velocity is reduced to enable dust & solid to settle out by the action of gravity. It is specially design a cylindrical or conical chamber.

 

Wet Scrubber: The wet scrubber unit is specially designed to remove the dispersoide from gases. In the conventional air washers the gas is passed through banks of sprays which may be directed down word, upward, into the gas stream, or with the gas stream. Consisting of the banks nozzles and water circulation pump. A set of zigzag eliminator is provided.

 

Dry Scrubber: The dry scrubber is designed for absorption of foul odor. When gases or air are moved through the system, the gases or air will be purified.

 

Ducting & I. D. Fan: The Ducting arrangements for flue gases complete with require dampers assembly and I.D. Fan will be provided.

 

Chimney: One heavy-duty chimney having 30-meter height from ground level to be incorporated along with the system completed with sampling port, platform & ladder, lighting arrester.

 

Electrical INCINERATOR PLANT

 

Model

MT-50

MT-51

MT-52

MT-53

MT-54

MT-55

MT-56

MT-57

Capacity per Hour

2.5 Kg

5 Kg

10 Kg

20 Kg

50 Kg

100 Kg

150 Kg

200 Kg

Temperature (Incinerator)

850°C

±50°C

850°C

±50°C

850°C

±50°C

850°C

±50°C

850°C

±50°C

850°C

±50°C

850°C

±50°C

850°C

±50°C

Temperature (Secondary Chamber)

1050°C

±50°C

1050°C

±50°C

1050°C

±50°C

1050°C

±50°C

1050°C

±50°C

1050°C

±50°C

1050°C

±50°C

1050°C

±50°C

Power Supply A.C. Main

440 Volt

3 phase

4 wire

440 Volt

3 phase

4 wire

440 Volt

3 phase

4 wire

440 Volt

3 phase

4 wire

440 Volt

3 phase

4 wire

440 Volt

3 phase

4 wire

440 Volt

3 phase

4 wire

440 Volt

3 phase

4 wire

Rating

3 KW per phase

5 KW per phase

7 KW per phase

9 KW per phase

18 KW per phase

30 KW per phase

45 KW per phase

60 KW per phase

Chimney (Stack Height Above Ground)

2 Meter

2 Meter

2 Meter

5 Meter

30 Meter

30 Meter

30 Meter

30 Meter

Space Req. Apprx. WxHxL

3' x 6' x 6'

3' x 6' x 6'

8' x 8' x 10'

10' x 10' x 15'

10' x 10' x 15'

10' x 15' x 15'

10' x 15' x 20'

15' x 20' x 20'

 

Any specific & larger sizes of Incinerator Plant can be manufactured as per customers requirement.

 

For Application in

  • Medical College & Hospital

  • Nursing Home & Clinic

  • Pharmaceuticals

  • Food Processing Units

  • Laboratories

  • Slaughter House

  • Hotel & Industrial