Products >> Exhaust Fans :
PASKO already an acknowledged leader in India for industrial fan manufacturing with its innovative design policy, which includes significant customer involvement, generates Exhaust Fans to guarantee quoted performance figures. Our main objective is to support top quality, value for money products, with the best technical back-up, literature, delivery and after sales service.

The product included in this catalogue is suitable for the following applications :

  • Industrial Ventilation

  • Condenser Cooling

  • Canteen Ventilation

  • Transformer Cooling

  • Evaporative Air Cooler

  • General Exhaust

  • Controlled Air Movement
  • Impellers :

    The newly designed impellers are manufactured by high precision accurately curved tools to maintain desired blade angles. Each and every impeller is dynamically balanced, tested and packed in the factory through a structured in-process quality control system

    Motor :

    The totally enclosed aluminum die cast heavy duty drive motor with rotor shaft mounted on two permanently lubricated ball bearings is specifically designed to cater desired fan performance with minimum power consumption.

    Accessories :

  • Louvre shutter

  • Wire guard

  • Wall cowl

  • RE units
  • etc.

    Positioning of Fan :

    The fans should be positioned so that fresh air drawn inside will permeate the entire room. Fans should not be installed in close proximity to doors or windows which are left open. In such cases, the air movement would be short circuited between the fans and adjacent inlets and therefore other parts of the room would remain non-ventilated.
    Therefore install the exhaust fan in a window or wall farthest from the door or other openings. Fresh air will then flow over the whole area.
    In kitchen, the best spot for the exhaust fan will be in the wall adjacent to, but not directly above the cooking range.
    In large occupied spaces, effective ventilation could be achieved if several small fans are installed rather than one or two large fans.

    FEATURES

  • 300, 380, 450, 610 and 915 mm. diameter.

  • 4, 6, 8 and 10 pole drive motor.

  • Volume of free air flow from 1200 cmh to 28000 cmh.

  • Static pressure up to 12mm.WG.

  • Rigid frame with rubber mountings for silent operation.

  • Maintenance free operation.

  • Dynamically balanced.

  • IP 55 protection with class-F insulation for outdoor use (optional).

  • Permanently lubricated double sealed ball bearing with a life of 40,000 hrs (app).

  • Accurately curved blade angles.

  • Special paint finish for enhanced corrosion resistance.

  • Aluminium die cast motor for light weight and corrosion resistance.

  • Variable mounting options to suit air flow direction.

  • Tropicalisation treatment (optional).

  • Thermal protection (optional).

  • Superior aesthetics.

  • Variable mounting options to suit air flow direction.

  • Ring / Diaphram mounting.

  • Voltage variation:± 10%

  • Frequency variation:± 5%


  • PERFORMANCE

    MODEL

    SWEEP


    (mm)

    PHASE 

     

    SPEED


    (rpm)

    VOLTAGE


    (volts)

    INPUT POWER

    (watts)

    CURRENT


    (amps)

    FREE AIR FLOW

    (m3 / hr.)

    PP3016

    PP3014

    300

    SINGLE

    SINGLE

    900

    1400

    230

    230

    50

    80

    0.22

    0.36

    1200

    2000

    PP3816

    PP3836

    PP3814

    PP3834

     

    380

    SINGLE

    THREE

    SINGLE

    THREE

    900

    900

    1400

    1400

    230

    415

    230

    415

    85

    85

    180

    180

    0.41

    0.20

    0.82

    0.40

    2500

    2500

    4200

    4200

    PP4516

    PP4536

    PP4514

    PP4534

     

    450

    SINGLE

    THREE

    SINGLE

    THREE

    900

    900

    1400

    1400

    230

    415

    230

    415

    132

    132

    372

    372

    0.60

    0.30

    1.75

    0.82

    4500

    4500

    7000

    7000

    PP6136

    PP6116

    PP6118

    PP6138

     

    610

    THREE

    SINGLE

    SINGLE

    THREE

    900

    900

    700

    700

    415

    230

    230

    415

    500

    500

    240

    240

    1.0

    2.3

    1.1

    0.5

    10450

    10450

    7900

    7900

    PP9138

    PP91310

    915

    THREE

    THREE

    700

    550

    415

    415

    1200

    700

    2.5

    1.5

    28000

    22100


    VENTILATION REQUIREMENT

    Ventilation implies fresh air supply or extraction of air. The rate of ventilation commonly measured in cubic meter per hour should be sufficient to meet the following requirements.

    Extraction of Air

    Supply of Fresh Air


    A combination of both of extraction and supply.
    For a large room it is recommended to use a number of smaller fans at different locations rather than one or two large fans for effective and adequate ventilation.

    Mounting

    Pasko exhaust fan can be mounted either vertically or horizontally and is suitable for delivering air either from or towards the motor.

    Roof Extractor

    Pasko Exhaust fans are effectively used as Roof Exhausters as well to dispel air from within a room using suitable and attractive domes fixed on the roof.